Spring, to be armed
Spring sniper: hard or unarmed head
The head force, no longer locks, or the shot starts when it closes.
- Verifications
- 3
- Until
- Dismantling
- Tools
- 3
Symptoms
- Very hard to shoot, with hard points
- The head does not remain armed: the piston (definition) goes forward
- Shooting starts by closing the head
Causes
Most common to rare.
- Too powerful spring (definition) or dry cylinder (definition)Common
- Used or poorly adjusted trigger (sear (definition))Possible
- Scrape or grease (definition) hardened in the cylinderPossible
Verifications
0/3
In the order: we start with what does not require anything to disassemble. Check as you go, the list is kept in this browser.
A head that doesn't hold the weapon can get the shot off at any time. Remove the charger and point to the ground throughout the diagnosis.
Without toolsCautionCylinder out, remove the old grease, then a thin layer of silicone grease on the piston seal and spring guide (definition).
DismantlingTools: Precision screwdriver, Gearbox fat, Isopropyl alcoholThe contact (definition) angles shall be clear. A trigger rounded by wear loosens the plunger; with a reinforced spring, prefer a metal trigger.
DismantlingTools: Precision screwdriver
Stop
Stop and hand over the reply to a technician if:
- Shooting starts on its own: no longer use the replica before repair
- The spring is very powerful: its dismantling requires a suitable tool