Toolbox

Discover our practical tools to improve your airsoft experience

AEG, electric, HPA, compressed air

Two balls leave at the same time

Double power supply: two balls enter the chamber, range and accuracy collapse on these shots.

Verifications
4
Until
Dismantling
Tools
1

Symptoms

  • Two balls visible at the same shot, leaving in different directions
  • Some shots fall a few meters away
  • Balls roll out of the replica gun pointed down

Causes

Most common to rare.

  1. Loader that grows too strong : hi-cap too raised, spring (definition) too stiffCommon
  2. Used or too soft Bucking (definition) that no longer holds the ballCommon
  3. Bills too light or of irregular diameterPossible
  4. Nozzle (definition) too short, often after changing partsPossible
  5. Weary flat tappet spring: the nozzle returns too slowlyRare

Verifications

0/4

In the order: we start with what does not require anything to disassemble. Check as you go, the list is kept in this browser.

  1. A few spins are enough. If the defect disappears with a mid-cap, it is the loader pressure that forces the second ball.

    Without tools
  2. Polished balls of regular weight stand better in the room than entry-level balls.

    Without tools
  3. Hop-up (definition) disassembled, the lip holding the ball must be supple and intact. Also check that the fucking is straight on the cannon, without a spin.

    Simple toolsTools: Precision screwdriver
  4. Gearbox open: the length of the nozzle depends on the replica. Too short, he lets pass a second ball; its joint must also be intact.

    DismantlingTools: Precision screwdriver

Stop

Stop and hand over the reply to a technician if:

  • The nozzle is to be changed and you do not know the appropriate length