HPA: Do not shoot or shoot weak
The HPA engine is either powerless or no longer reacting.
- Verifications
- 4
- Until
- Simple tools
- Tools
- 3
Symptoms
- No reaction to relaxation
- Very weak or irregular firing
- The sound of the solenoid is present, but not the breath
Causes
Most common to rare.
- Empty bottle, closed or badly screwed line (definition)Common
- Pressure of regulator too lowCommon
- Empty electronics batteryCommon
- Dwell too short for pressure and cannonPossible
- Flight on line or in HPA (definition) enginePossible
Verifications
In the order: we start with what does not require anything to disassemble. Check as you go, the list is kept in this browser.
Open bottle, regulator gauge in the range provided by its manufacturer, fully screwed fittings.
Without toolsA small LiPo (definition) is enough but emptys quickly in storage. Too low a voltage, the solenoid no longer opens properly.
Without toolsTools: Balancer chargerPressure first, within the manufacturer's range; dwell then, following the calculator. Check the chronograph power after each change.
Simple toolsTools: ChronographSee the fact sheet on air leaks: a whistle, even discreet, causes the pressure to drop at the time of firing.
Simple toolsTools: Soap water
Stop
Stop and hand over the reply to a technician if:
- The regulator or HPA engine must be dismantled: depress before, and in case of doubt entrust it