Toolbox

Discover our practical tools to improve your airsoft experience

AEG, electric, HPA, compressed air, Spring, to be armed

The charger no longer feeds

The charger is full but no longer pushes the balls, or only at once.

Verifications
4
Until
Simple tools
Tools
2

Symptoms

  • The wheel of the hi-cap rotates effortlessly or no longer rises
  • The balls stop in the charger, which remains half full
  • The charger works in one replica and not in the other.

Causes

Most common to rare.

  1. Bad or deformed billes that block the climbCommon
  2. Loader's lips apart or twistedPossible
  3. Relaxed or broken hi-cap spring (definition)Possible
  4. Charger not suitable for replica (brand, model)Possible

Verifications

0/4

In the order: we start with what does not require anything to disassemble. Check as you go, the list is kept in this browser.

  1. Balls collected on the ground or wet block the climb. Just recharge clean balls out of the bag.

    Without tools
  2. If it works, it is the charger shaft or the lock of the first replica that prevents it from engaging properly.

    Without tools
  3. They must hold the ball from the top without pinching it. Torded by a fall, they drop the balls or block them.

    Without tools
  4. Disassembled, rinsed with soapy water and then dried completely. No oily lubricant: it glues dust and balls.

    Simple toolsTools: Precision screwdriver, Soap water

Stop

Stop and hand over the reply to a technician if:

  • The spring spring of a hi-cap is broken: the charger replaces itself, its repair is rarely profitable